Mfg Part Number: C11620-5350-3451 | Alternate P/N: C1162053503451 |
NSN : 5905-01-061-8033 | NIIN : 010618033 |
CAGE Code : 04274 | Manufacturer: Rosemount Inc |
Item Name : Resistor Fixed Wire | FSC : 5905 Resistors |
Thank you for your interest in acquiring NSN parts and components from Stacked Hardware. NSN 5905-01-061-8033 is listed alongside the part number C11620-5350-3451, having been manufactured by Rosemount Inc. If you would like to purchase this part or any other specialized items related to Resistor Fixed Wire from our catalog, we invite you to complete and submit an RFQ form as provided below for part C11620-5350-3451. Upon completing the form, we ask that you provide as many details as you can about the parts or components you wish to procure such as target prices, desired quantities, and expected shipping time frames. With such information, our team of dedicated account managers can draft a solution that keeps your unique requirements in mind.
The particular Rosemount Inc part like C11620-5350-3451 you wish to purchase was produced under CAGE Code 04274. The quality of our offerings is guaranteed by our strict NO CHINA SOURCING pledge and the countless quality assurance measures our items are subject to prior to shipping out to our customers. We proudly operate as an AS9120B, ISO 9001:2015, and FAA AC 00-56B certified enterprise, ensuring that you are getting exactly what you need when you need it. Complete an RFQ form today for NSN 5905-01-061-8033 or contact one of our dedicated representatives to see how Stacked Hardware can help you with all your operational needs.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-01-061-8033 Item Description: Resistor Fixed Wire | 5905 | 010618033 | 0 | N | B | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | B | U | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
C11620-5350-3451 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -20.0/+20.0 |
AAPP | ELECTRICAL RESISTANCE | 5.350 KILOHMS |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000/+1.000 |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0 |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+275.0 |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AARB | TERMINAL TYPE | WIRE LEAD |
AARE | REACTANCE CHARACTERISTIC | INDUCTIVE |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABJT | TERMINAL LENGTH | 1.500 INCHES NOMINAL |
ABPM | BODY DIAMETER | 0.078 INCHES MINIMUM AND 0.108 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.375 INCHES MINIMUM AND 0.437 INCHES MAXIMUM |
AEFB | POWER DISSIPATION RATING IN WATTS | 0.500 FREE AIR |
AFWW | TERMINAL WIDTH | 0.023 INCHES MINIMUM AND 0.027 INCHES MAXIMUM |
CBME | CUBIC MEASURE | 0.003 CUBIC INCHES |
PKWT | UNPACKAGED UNIT WEIGHT | 0.414 GRAMS |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
TEST | TEST DATA DOCUMENT | 04274-C11620 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWI |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.